Brass Normally Open Water Solenoid Valve 2 Way Low Voltage For Hydraulic System 

Place of Origin: Zhejiang, China (Mainland) 
inquire
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Model No.: ZW

 
ZW series 2-way semi direct acting ( NO ) solenoid valve
 
Water solenoid valve Feat

 

ZW series 2-way semi direct acting ( NO ) solenoid valve

 

Water solenoid valve Features:


Simple structure, small size, good sealing performance, easy maintenance.

 

 

working medium:water,liquid,air,light oil(viscosity≤20cst)

medium temperature:-5 80

working pressure:0 6 bar

working type:semi direct acting(NO)

valvebody material:forged brass SS304

sealing material:NBR

interface:G thread NPT thread

working voltage:AC220240V AC110V 50/60Hz DC24/12V IP65 H degree

DN1020 AC 28VA DC 18W DN2550 AC 45VA DC 31W

options:EPDM(-10130)

VITON(-10120)

Rc thread Es low power energy saving coil lead wire iron coil

 

 

 

 

ZW-series(NO)solenoid valve specification table

model

orifice size

( mm )

interface size Cv working pressure (bar

length×width×height

( mm )

Weight (Kg)
AC220V DC24V brass SS304
ZW-10NK 15 3/8 3.5 06 06 60×45×109 0.75 0.7
ZW-15NK 15 1/2 3.5 06 06 60×45×109 0.75 0.7
ZW-20NK 20 3/4 7.6 06 06 67×50×119 0.8 0.75
ZW-25NK 25 1 12 06 06 82×66×127 1.3 1.1
ZW-32NK 32 11/4 24 06 06 102×82×162 2.2 2.0
ZW-40NK 40 11/2 29 06 06 110×85×168 2.5 2.3
ZW-50NK 50 2 48 06 06 134×108×182 3.3 3.1

 

 

Water solenoid valve use and maintenance:
1, it is recommended to use the unit to send the person responsible for maintenance.
2, the solenoid valve is installed into the media need to pass several experimental action shall be put into use after confirming normal.
3, large internal and external valve should be cleaned regularly and the title of the pull side of the dirt, careful not to damage the sealing surface.
4, when the solenoid valve is a long time to do, should be closed before the valve manual valve, when re-enabled, steam solenoid valve should condensate removal and clean, and make trial action several times, only to be put into use after the switch to normal.
5, when the solenoid valve from the pipeline do not remove, the internal parts should be scrubbed and blowing with compressed air storage.
6, when used for a long time, such as a seal between the piston and the valve seat is bad, the piston sealing surface re-polished, and now seat grinding.
7, in operation, should pay attention to before and after the valve pressure gauge required working pressure must not exceed the rated pressure, working pressure must be within the rated pressure range. When the operating pressure exceeds the rated pressure or working pressure exceeds the rated pressure, the solenoid valve to stop using closed before and after manual valves, solenoid valves to prevent explosions and leaks.

bigPhoto
 Mr. Miss. Ying

Tel: 86-574-62833672
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

Yuyao No. 4 Instrument Factory [China (Mainland)]


Business Type:Manufacturer
City: Ningbo
Province/State: Zhejiang
Country/Region: China (Mainland)

You May Like:

Product (210)